With the Automatic Flushing-System your drinking system is flushed by itself. With the LUBING controller LCW-8 item 4480, you can flush up to 8 drinking lines separately. This system can be easily retrofitted into existing drinking systems.
Need components
1. The LUBING controller LCW-8 art. 4480
With the controller the following values can be adjusted to the individual needs:
- The duration of the flushing. With that you can adjusted the required time for a sufficient flushing depending on the length of the drinking lines and thus avoid waste water also during the flushing.
- The time of flushing.
- Each drinking line is flushed separately (it is possible to flush several drinking lines at the same time by clamping them to the same contact).
Requirements: Approx. 1 litre for 4 meter length of drinking line (nipple pipe 22x22)
2. The flush kit - art. 4166
The solenoid valve (dead closed) is also attached to the supply line of the pressure regulator. The entire unit between the water supply hose and the pressure regulator is delivered pre-assembled.
To control the solenoid valve a cable must be attached to the LUBING controller LCW-8. (230 V, 50 Hz)
Alternatively: Flush kit
art. 4166-1 with 24 V solenoid valve.
3. The flush breather unit - art. 4255-00
For the automatic flushing a new breather unit has been developed. This is fastened to the end of the drinking line.
The height of the water column is shown by a red ball in the breather.
Trough the drain kit the flushing water is led to the drainpipe.